Ultrasonic Testing System
The high frequency (HF) ultrasound device consists of a scanning system with immersion basin, the external transmitter and receiver unit. Using the pulse-echo method, high-resolution interference points are detected on thin samples (depending on the material, up to a maximum of 5 mm) and visualized at the precise location using digital imaging. Among other things, it is used for testing the early damage markers delamination, blistering and rust on varnish layers. Furthermore, adhesion problems in adhesive and fiber composite systems can be detected.
Application Examples
- Non-destructive testing
- Damage analysis of thin components as well as welded and soldered joints
- Detection of incipient corrosion attack on varnish-coated samples in stress test
- Investigation of laminates, fiber, composites, bondings
Are you looking for more information or do you have any questions about our R&D and service portfolio?
Then do not hesitate to contact us by phone or e-mail.
- GCMS
- HPLC
- GPC
- IC
- Atomic Force Microscopy
- 3D Microscopy
- Light microscopy
- IR spectroscopy (microscope, ATR)
- Raman Spectroscpoy
- X-ray fluorescence spectroscopy
- Fluorescence spectroscopy
- UV/Vis spectroscopy
- Thermal analysis
- Karl Fischer Titration
- Titrimetry/volumetry
- Permeation measurement
- Universal Testing Machines
- Buchholz Hardness Test
- Scratch & Scribing Tools
- Shore Hardness Test
- Mandrel Bending Test
- Cross Cutting Test
- Ultrasonic Testing System
- Colorimeter/structure measuring device
- Gloss Level Analysis
- Grind Gages (Grindometer)
- Coating Thickness Measurement
- Potentiostat/Galvanostat
- Measurement of Corrosion Current
- TERA Ohmmeter
- Constant climate/climate change test
- Temperature shock test
- Autoclave/steam sterilization tests
- High-performance drying oven for hot air short cycle
- Corrosion test chamber
- UV tester
- Xenon tester
- Outdoor weathering
- Ozone resistance
- Scrub test
- Chemical resistance
- Abrasion/wear resistance
- Cupping test
- Drop Ball Impact Test
- Coater
- Mechanochemical Surface Treatment
- Powder Coating
- Pneumatic Hot-melt Dispenser
- Irradiation technology
- Speedmixer
- Dispermat/Dissolver
- Palamat
- granulate pre-treatment
- compounder/extruder
- hybrid/injection molding
- Panel press
- Cryomill
- Sample preparation technique
- Cross-section preparation
Manufacturer
Ingenieurbüro Dr. Hillger Braunschweig
Model:
USPC 3060 UHF

Dr. Joerg Leuthaeusser
Head of Department
Analytics – Materials – Composites
JL@innovent-jena.de
Phone: +49 3641 2825 48