Potentiostat / Galvanostat
The term electrochemical noise is used at corrosion studies to describe the nucleation processes and their healing. These processes correlate to small electrically measurable pulses (events). The analysis methods used are, e.g. event counting, standard deviation or evaluation in the frequency range.
The special feature of measuring electrochemical noise compared to other methods of electrochemical corrosion testing is that the gain in information can be obtained without external excitation of the system (potential noise). The high sensitivity of the test method enables, e.g., the initiation processes of local corrosion phenomena on passive metal surfaces to be determined.
Causes of the electrochemical noise on passive metals are activation and re-passivation processes of the passive layer respectively the hereby caused fluctuations of the charge at the phase boundary interface metal-(passive layer) / electrolyte. Depending on the experimental setup, these charge fluctuations can be measured as noise of current or potential.
Technical Overview:
- Potentiostat, Galvanostat
- 10 current ranges: up to 100 pA
- Maximum: ±12 V / ±100 mA
- Resolution: 0,01 pA ( theoretical)
- Instruments for U and I
- Internal nominal voltage generator and 2 nominal voltage inputs
The PGU 100‑PCR is suitable as normal potentiostat / galvanostat as well as for measurement of the electrochemical noise (potential and current noise). The device is equipped with switchable amplifiers for both potential noise (× 100 / 500 / 1000 / 2000 / 5000 / 10000) and current noise (× 10 / 20 / 50 / 100 / 200 / 500). The lower cut-off frequency is permanently set to 0.1 Hz (0.01 Hz). The upper cut-off frequency can be switched in six different ranges (1 / 10 / 40 / 100 / 200 / 500 Hz).
Possible methods and measurements:
- Potential noise
- Current noise (external currentless)
- Both potential‑ and current noise (without external current)
- Current noise under potentiostatic control
- Potential noise under galvanostatic control
Are you looking for more information or do you have any questions about our R&D and service portfolio?
Then do not hesitate to contact us by phone or e-mail.
- GCMS
- HPLC
- GPC
- IC
- Atomic Force Microscopy
- 3D Microscopy
- Light microscopy
- IR spectroscopy (microscope, ATR)
- Raman Spectroscpoy
- X-ray fluorescence spectroscopy
- Fluorescence spectroscopy
- UV/Vis spectroscopy
- Thermal analysis
- Karl Fischer Titration
- Titrimetry/volumetry
- Permeation measurement
- Universal Testing Machines
- Buchholz Hardness Test
- Scratch & Scribing Tools
- Shore Hardness Test
- Mandrel Bending Test
- Cross Cutting Test
- Ultrasonic Testing System
- Colorimeter/structure measuring device
- Gloss Level Analysis
- Grind Gages (Grindometer)
- Coating Thickness Measurement
- Potentiostat/Galvanostat
- Measurement of Corrosion Current
- TERA Ohmmeter
- Constant climate/climate change test
- Temperature shock test
- Autoclave/steam sterilization tests
- High-performance drying oven for hot air short cycle
- Corrosion test chamber
- UV tester
- Xenon tester
- Outdoor weathering
- Ozone resistance
- Scrub test
- Chemical resistance
- Abrasion/wear resistance
- Cupping test
- Drop Ball Impact Test
- Coater
- Mechanochemical Surface Treatment
- Powder Coating
- Pneumatic Hot-melt Dispenser
- Irradiation technology
- Speedmixer
- Dispermat/Dissolver
- Palamat
- granulate pre-treatment
- compounder/extruder
- hybrid/injection molding
- Panel press
- Cryomill
- Sample preparation technique
- Cross-section preparation
Manufacturer:
IPS Elektroniklabor GmbH
Model:
PGU-100PCR

Dr. Joerg Leuthaeusser
Head of Department
Analytics – Materials – Composites
JL@innovent-jena.de
Phone: +49 3641 2825 48

Dr. Evelyn Kaemmer
Head of Department
Analytics – Materials – Composites
E.Kaemmer@innovent-jena.de
Phone: +49 3641 2825 57